Portable,Turbidimeter,HF Scientific,Model,DRT-15CE

Portable Turbidimeter HF Scientific Model DRT-15CE

DRT-15CE Portable Turbidimeter
STANDARD FEATURES:
Rugged Portable Carrying Case
Ensures durability and convenience no matter where your laboratory happens to be.

Completely Self-Contained
Provides easy access to everything you need to take a measurement.

Three User Selectable Ranges
Provides accuracy in a wide variety of applications from 0 to 1000 NTU.

20 Hour Rechargeable Battery
Always be ready to go with up to 20 hours of continuous operation when fully charged.

Made in the USA

OPTIONAL FEATURES:
Automobile Adapter
Charge and operate the DRT-15CE from the cigarette lighter in your automobile.

Formazin Stock Solution Kit
Contains everything you need to calibrate the DRT-15CE with Formazin, the primary calibration standard.

SPECIFICATIONS
Range: 0 - 10 NTU 0 - 100 NTU 0 - 1000 NTU
Accuracy: 0-10 NTU, ± 1% of full scale 0-100 NTU, ± 5% of full scale 0-1000 NTU, ± 10% of full scale
Resolution: 0.1% of selected range
Response Time: Immediate
Sample Size: 25 ml (16 ml minimum)
Operating Temperature: 32- - 122-F (0- - 50-C)
Battery: 6V gel-cell rechargeable with 20 hours of continuous use when fully charged.
Recharge Time: 8 hours to full charge
Dimensions: 11 x 8 x 5 _ inches (28 x 20 x 14 cm)
Weight: 5 lbs (2.27 kg)
Standards Compliance: USEPA, CE Approved

Portable,Turbidimeter,HF Scientific,Model,DRT-15CE

Designed to provide the rugged portability needed in the field with the accuracy demanded in the laboratory, the EPA approved* DRT-15CE has become a "must have" for anyone monitoring turbidity on the go. The integral carrying case holds everything needed for field operation. With resolution of 0.01 NTU and an extended range to 1,000 NTU, the DRT-15CE is a perfect fit for both field and laboratory use.

* The DRT-15CE exceeds performance criteria specified by US EPA method 180.1 for NTU measurement

Literature and Specifications
Operator's Manual

 

DRT-15CE Instruments and Accessories

Catalog Number                            Description
Instruments
19057 Portable Turbidimeter (0 - 1000) NTU (120V)
19058 Portable Turbidimeter (0 - 1000) NTU (240V)
Note: Both of above include a battery charger, sample cuvette with light shield cap, 0.02 NTU
        reference standard, recorder output plug, and instruction manual.
Accessories
20115 Adapter Kit, 16mm factory installed
19045 Auto Adapter 12 Volt
70050 Battery Charger - 120V
19046 Battery Charger - 240 V European Standard
19071 Calibration Set (0.02, 10, 100, & 1000 NTU)
19843 Calibration Standard, 0.5 NTU (Nominal Value)
19825 Calibration Standard, 10.0 NTU
19824 Calibration Standard, 100 NTU
19831 Calibration Standard, 1000 NTU
50048 Cuvette 16mm 3/pk. with cap shields (requires adapter, catalog no. 20115)
50052 Cuvette 28 x 70mm 10/pk. (replaces 28 x 93mm) Use for grab sample. Includes 10 threaded light shield caps.
50051 Cuvette 28 x 70mm 3/pk. (replaces 28 x 93mm) Use for grb sample. Includes threaded light shield caps.
19981 Cuvette Stand for storing empty cuvettes as well as calibration standards; holds up to 11 cuvettes.
50040 Formazin Stock Solution Kit. Each kit contains 32 ounces of 4000 NTU Formazin, one gallon 0.02 NTU water, one 0.02 NTU Reference Standard, four cuvettes with indexing light shields, three pipettes, and instruction manual.
21805 Instruction Manual
27051 Kim Wipe 280/box
50009 Light Shield (not threaded for use with 28 x 93mm cuvettes)
19975 Pour Through Assembly (includes the assembly, locking ring, 24" of drain tubing, cuvettes and instructions)
70008 Rechargeable Battery
60002 Reference Standard 0.02 NTU (Complete with indexing light shield.)
21084 Source Lamp Assembly, 2/pk.