Micro 100 Laboratory Turbidimeter
|
STANDARD FEATURES:
Auto Ranging 0 - 1000 NTU
Instrument senses turbidity level of sample and automatically adjusts to the appropriate measurement.
Auto Alert Calibration Prompt
Automatically prompts the operator when calibration of the instrument is needed.
Simple Calibration Procedures
Calibration initiated with the push of a button ensures accurate readings.
RS-232 Output
Date, time, and NTU reading can be captured with a serial printer or data recorder.
Made in the USA
OPTIONAL FEATURES:
Infrared Light Source (Micro 100IR)
Meets international standard ISO 7027 for turbidity measurement.
Pour-through assembly
Save time by pouring your grab sample through the measurement chamber.
Reusable Calibration Standards
Quick and easy calibration across all ranges without the need to mix Formazin. |
SPECIFICATIONS
|
Principal of Operation: |
Nephelometric non-ratio |
Range: |
Auto ranging from 0 - 1000 NTU |
Accuracy: |
± 2% of reading plus 0.01 NTU |
Resolution: |
0.01 NTU (0 - 9.99 NTU) 0.1 NTU (10 - 99.9 NTU) 1 NTU (100 - 1000 NTU) |
Response Time: |
< 6 seconds |
Sample Size: |
30 ml (27ml minimum) |
Light Source: |
Quick connect Tungsten Filament or Infrared Operating |
Temperature: |
32° - 122°F (0° - 50°C) |
Outputs: |
RS-232 Serial Port |
Dimensions: |
10.75 x 10 x 3.75 inches (27.3 x 25.4 x 9.5 cm) |
Weight: |
2.9 lbs. (1.32 kg) |
Safety rating: |
UL, CSA, CE |
|
Designed to provide the accuracy demanded by today's scientist, the Micro 100 Laboratory Turbidimeter is ready to meet the challenge. Features like the Auto Alert Calibration Prompt and the Quick Connection Lamp Module, allow for simple calibration and low maintenance. With a resolution of 0.01 NTU at low turbidity readings and an extended range to 1,000 NTU, the Micro 100is an ideal and affordable tool for research as well as routine analytical measurements.
Optional pour through assembly
Note: The Micro 100meets performance criteria specified by USEPA method 180.1 for NTU measurement and ISO7027 (IR version).
Literature and Specifications
Operator's Manual
|
Micro 100 Instruments and Accessories
Catalog
Number
|
Description
|
|
Instruments |
20001 |
Micro 100 White Light Laboratory Turbidimeter, 110V, 60Hz |
19950 |
Micro 100 White Light Laboratory Turbidimeter, 100 - 240V, Universal Power 50 - 60Hz |
|
|
19951 |
Micro 100 Infrared Laboratory Turbidimeter, 110V, 60Hz |
19952 |
Micro 100 Infrared Laboratory Turbidimeter, 100 - 240V, Universal Power 50 - 60Hz |
|
Note: All four of the above include a complete set of calibration standards (0.02, 10, and 1000 NTU), two measuring cuvettes with light shield caps, and an operator's manual. The 110V, 60Hz instruments include a 110 VAC power adapter. The 100 - 240V, 50 - 60Hz instruments include a universal power adapter that operates at any voltage between 100 - 240 VAC. |
|
Accessories |
19786 |
Batteries, Lithium 2/pk. |
19785 |
Cable RS-232 |
|
|
19961 |
Calibration Set, IR (0.02, 10 and 1000 NTU) |
19957 |
Calibration Set, White Light (0.02, 10 and 1000 NTU) |
62017 |
Calibration Standard, IR (10 NTU) |
62018 |
Calibration Standard, IR (1000 NTU) |
19825 |
Calibration Standard (10 NTU) |
19831 |
Calibration Standard (1000 NTU) |
|
|
50052 |
Cuvette 28 x 70mm 10/pk. (replaces 28 x 93mm) Use for grab sample. Includes ten threaded light shield caps. |
50051 |
Cuvette 28 x 70mm 3/pk. (replaces 28 x 93mm) Use for grab sample. Includes threaded light shield caps. |
19981 |
Cuvette Stand for storing empty cuvettes as well as calibration standards; holds up to 11 cuvettes. |
|
|
50040 |
Formazin Stock Solution Kit. Each kit contains 32 ounces of 4000 NTU Formazin, one gallon 0.02 NTU water, one 0.02 NTU Reference Standard, four cuvettes with indexing light shields, three pipettes, and an instruction manual. |
22155 |
Instruction Manual (White light and IR) |
19975 |
Pour through Assembly. Includes the assembly, locking ring, 24" of drain tubing, cuvettes and instructions. |
60002 |
Reference Standard 0.02 NTU complete with indexing light shield. |
19972 |
Replacement Lamp Module (White Light) |
|
|