Micro 1000 Industrial Turbidimeter
|
STANDARD FEATURES:
Extended Auto Ranging up to 10,000 NTU
Instrument senses turbidity level of sample and automatically adjusts to the appropriate measurement.
Multiple Measurement Modes
NTU, EBC, and Nephelos, FNU, and FAU
Auto Alert Calibration Prompt
Automatically prompts the operator to initiate simple menu-driven calibration.
Built-in Diagnostics
Full time diagnostic software automatically monitors and detects errors.
Reusable Calibration Standards
Quick and easy calibration across all ranges without the need to mix Formazin.
Ratio (Color Correction)
Automatic compensation for background color.
Made in the USA
OPTIONAL FEATURES:
Pour Through & Flow Through Assemblies
Save time by pouring your grab sample through the measurement chamber or pressure feed using the flow through assembly. |
SPECIFICATIONS
|
Range: |
0 - 10,000 NTU
0 - 2,450 EBC
0 - 10,000 FNU
0 - 10,000 FAU |
Principal of Operation: |
Nephelometric |
Ratio (Color Correction): |
Full Time ON or OFF |
Accuracy: |
± 2% of reading plus 0.01 NTU (0 to 1000 NTU)
± 5% of reading (1000 to 4000 NTU)
± 10% of reading (4000 to 10,000 NTU) |
Resolution: |
0.0001 NTU on Lowest Range |
Response Time: |
less than 6 seconds |
Sample Size: |
30 ml |
Light Source: |
Quick connect Infrared |
Operating Temperature: |
32° - 122°F (0° - 50°C) |
Air Purge: |
Connection for external dry air supply |
Outputs: |
RS-232 Serial Port (Bidirectional) |
Shipping Dimensions: |
14 x 12 x 12 inches (35.5 x 30.4 x 30.5 cm) |
Weight: |
7.0 lbs. (3.18 kg) |
Certification: |
UL, CSA, CE, USEPA, ISO7027 |
|
Designed to provide the accuracy demanded in today’s laboratory, the Micro 1000 Ratio Turbidimeter is ready to meet the challenge. Features like the Auto Alert Calibration Prompt and the Quick Connection Lamp Module, allow for simple calibration and low maintenance. A full time ratio (color correction) mode is also featured. With a resolution of 0.0001 NTU at low turbidity readings and an extended range to 10,000 NTU, the Micro 1000 is an ideal and affordable tool for research as well as routine analytical measurements.
Literature and Specifications
Operator's Manual
|
Micro 1000 Instruments and Accessories
Catalog Number |
Description |
|
Instruments |
20013 |
Micro 1000 White Light Laboratory Turbidimeter (110V 60Hz Power Adapter) |
20014 |
Micro 1000 White Light Laboratory Turbidimeter (100 - 240V Universal Adapter) |
20015 |
Micro 1000 Infrared Laboratory Turbidimeter (110V 60Hz Power Adapter) |
20016 |
Micro 1000 Infrared Laboratory Turbidimeter (100 - 240V Universal Adapter 50 - 60Hz) |
|
Accessories |
19785 |
Cable RS-232 |
19927 |
Calibration Set, White Light (0.02, 10, 100, 1750 NTU) |
19825 |
Calibration Standard, White Light (10 NTU) |
22995 |
Calibration Standard, White Light (100 NTU) |
22997 |
Calibration Standard, White Light (1750 NTU) |
19938 |
Calibration Standard, White Light (10,000 NTU) |
|
|
19928 |
Calibration Set, Infrared (0.02, 10, 100, 1750 NTU) |
22994 |
Calibration Standard, Infrared (10 NTU) |
22996 |
Calibration Standard, Infrared (100 NTU) |
22998 |
Calibration Standard, Infrared (1750 NTU) |
19939 |
Calibration Standard, Infrared (10,000 NTU) |
|
|
50052 |
Cuvette 28 x 70mm 10/pk (Replaces 28 x 93mm) Use for grab sample. Includes ten threaded light shield caps. |
50051 |
Cuvette 28 x 70mm 3/pk (Replaces 28 x 93mm) Use for grab sample. Includes threaded light shield caps. |
19889 |
Flow Through Assembly (Complete kit) |
19975 |
Pour Through Assembly (Includes the assembly, locking ring, 24" of drain tubing, cuvettes and instructions.) |
60002 |
Reference Standard 0.02 NTU (Complete with indexing light shield.) |
19972 |
Replacement Lamp Module (White Light) |
|