CLX OnLine Residual Chlorine Monitor From HF Scientific

User selectable features and innovative design sets the new CLX OnLine Residual Chlorine Monitor apart from the competition.  Cycle times that are adjustable from 90 seconds to 10 minutes, 4-20mA and Modbus outputs that can control feed pumps and user settable alarms equates to low operating and maintenance costs.  A new flow through design maintains cuvette cleanliness and allows for viewing of optical operations.  The strong, shatterproof case that opens to facilitate reagent replacement also allows easy access to all service functions which reduces maintenance time.  Unattended operation and low chemical usage equates to low operating cost.

STANDARD FEATURES:
Free or Total Chlorine:
Can be used to measure Free or Total Chlorine.

Low Operating Costs:
Low Reagent use translates into low operating cost of pennies a day.

User Selectable Cycle Times:
Cycle times can vary between 110 seconds and 10 minutes.

Colorimetric DPD Chemistry:

Uses inexpensive DPD chemistry rather than expensive electrodes.

Simple Operation:

Designed for unattended operation up to 30 days.

Microprocessor Based Technology:

Microprocessor based technology ensures high quality at the industry's lowest price.

Drinking Water, Wastewater and More:

Alarms:

Two user selectable alarms for sample concentration.

4-20mA and RS-485 Modbus

USEPA Accepted

Made in the USA

 

CLX,OnLine,Residual,Chlorine,Monitor,HF,Scientific

The CLX OnLine Residual Chlorine Monitor comes complete with an operating manual.

Reagents must be purchased separately.

If the application combines high humidity with cold sample water, purchase a #09944 Desiccant Cartridge separately.

CLX,OnLine,Residual,Chlorine,Monitor,HF,Scientific

CLX Open View

CLX,OnLine,Residual,Chlorine,Monitor,HF,Scientific

CLX Reagent Kit

SPECIFICATIONS
Range: 0 - 10 mg/l
Cycle Time: User Selectable: 110 seconds - 10 Minutes
Accuracy:

0-6 mg/l - ±5% or 0.03 mg/l of CL2 whichever is greater

6-10 mg/l - ±10% or 0.06 mg/l if CL2 whichever is greater

Resolution: 0.01 mg/l
Method: USEPA accepted DPD method of analysis for measuring Free or Total Residual Chlorine
Standard Outputs: 4-20 mA and RS-485 with Modbus
User Alarms: 2 User Selectable Alarms for Sample Concentration
Operating Temperature: 5° - 40°C (41° to 104°F)
Input Pressure: 5 - 150 psi
Enclosure: ABS Plastic, Nema 4X, IP66
Power: 100 - 240 Volt Auto Switchable 47 - 63hz
Certifications: CE, UL, CSA,(ETL, ETLc)
Shipping Dimensions: 16" x 16" x 10"  (41cm x 41cm x 26cm)
Shipping Weight: 8 lbs (3.6 kg)

CLX Literature
CLX Full Specifications Document
CLX Operators Manual
CLX Modbus Manual

CLX Instruments and Accessories
Instrument
20040 CLX OnLine Chlorine Residual Monitor for Free of Total Chlorine
Accessories
09951 Kit Reagent - Free Chlorine  30 day supply - New JAW (Just Add Water)
09952 Kit Reagent - Total Chlorine  30 day supply - New JAW (Just Add Water)
09953 Kit Reagent - Free Chlorine  60 day supply - New JAW (Just Add Water)
09954 Kit Reagent - Total Chlorine  60 day supply - New JAW (Just Add Water)
09955 Kit Reagent - Free Chlorine  12 month supply - New JAW (Just Add Water)
09956 Kit Reagent - Total Chlorine  12 month supply - New JAW (Just Add Water)
 
09947 Kit Reagent - Free Chlorine  30 day supply - Original Liquid
09948 Kit Reagent - Total Chlorine  30 day supply - Original Liquid
09935 Kit Reagent - Free Chlorine  60 day supply - Original Liquid
09936 Kit Reagent - Total Chlorine  60 day supply - Original Liquid
09937 Kit Reagent - Free Chlorine  12 month supply - Original Liquid
09938 Kit Reagent - Total Chlorine  12 month supply - Original Liquid
09939 Replacement Tubing / Cuvette Kit
09944 Desiccant Cartridge
25018 Flow Through Cuvette CLX
25017S Check Valve Kit - For CLXs shipped after AUG 2007. Includes Check Valves, Duck Bill Valves, End Caps and Pump Tubes
24474S Check Valve
98878 Demo Stand
24429S Replacement PCB Module - Includes LCD, Keypad, Pump & Tubing
09945 Zero Calibration Kit 240 Volt  50cps